Rising arm barrier
Draft: to be checked by UrbanForte before use.
- Uniclass system
- Ss_25_36_95_70 Rising arm barrier systems
- Uniclass product
- Pr_30_59_59_72 Rising arm vehicular barriers
- CAWS work section
- Q41 Barriers/guardrails (CAWS work section, historical title)
- NRM1
- 8.4.4 Barriers and guardrails (mapping from the NBS Uniclass Systems table v1.44; not checked against the RICS publication)
- NRM2
- Project QS to confirm.
- CPV, supply
- 34926000-4 Car park control equipment (for car-park entry/exit control)
- CPV, installation
- 51100000-3 Installation services of electrical and mechanical equipment (for a separately procured equipment-installation service); 45233280-5 Erection of road-barriers (only where the work genuinely matches road-barrier works)
- CPV, maintenance
- 50610000-4 Repair and maintenance services of security equipment (where the assets are security/access equipment)
Short clause
Supply, install, test and commission [number] automatic rising arm barrier(s) at [location], complete with drive unit, arm, controls, safety devices, signage and accessories. Work included: [list]. Work by others: [list]. Select safety devices from the site risk assessment and provide [separate pedestrian route / guarding / signage] as specified in the full clause. Test controls, interfaces, safety devices, power-failure operation and manual release, with force testing where required. Provide the clause 11 handover pack, with the technical file retained by the installer acting as manufacturer. Train [number] client nominees and record attendance.
Full clause
1.1 Scope Supply, install, test and commission [number] automatic rising arm barrier(s) at [location], complete with drive unit, arm, controls, safety devices, signage and all accessories needed for a safe, working installation. Work included: [list]. Work by others: [list]. 1.2 Description - Barrier type: automatic rising arm barrier, [left / right]-hand as viewed from [direction]. - Clear opening to be controlled: [width] m. - Arm: [type, e.g. straight / articulated / folding], length [length] m, material [material], [with / without] arm lights, [with / without] skirt or lower guard, [with / without] arm rest at the free end. - Cabinet / housing: [material], [finish], [colour]. - Duty: suitable for [description of use, e.g. car park entry / site entrance] with [number] operating cycles per [hour / day]. - Arm breakaway or release: [required / not required]. - Manual release for use during power failure: [type], operable by persons permitted by the client only. 1.3 Performance requirements - Opening time: [time] seconds. Closing time: [time] seconds. - Operating cycles: rated for at least [number] cycles per [period] without overheating. - Wind: arm to remain stable and operable in wind speeds up to [speed] at the site location. - Operating temperature range: [range] °C. - Ingress protection of housing and electrical components: [IP rating]. - Power failure behaviour: [fail open / fail closed / stay in last position], with [battery back-up for number of cycles / no battery back-up]. - The equipment must be designed, installed and commissioned so that the risks of impact, crushing, shearing, drawing-in and lifting are reduced to an acceptable level, as shown by the risk assessment and force testing. 1.4 Standards and legislation Comply with the current editions of the following, as relevant: - Supply of Machinery (Safety) Regulations 2008 (as amended). The completed powered installation is machinery. The installer who completes it and acts as manufacturer must meet the manufacturer's duties, compile and retain the technical file for the enforcing authorities, and provide the client with the declaration of conformity and user and maintenance instructions in English. Apply UKCA or CE marking under the applicable Great Britain conformity route. SI 2026 No. 867 comes into force on 20 January 2027: Part 2 amends the Great Britain regime, including recognition of specified compliance routes under Regulation (EU) 2023/1230; Part 3 provides Northern Ireland enforcement and revokes the 2008 Regulations for Northern Ireland only, subject to transitional provisions. Check the regime applicable at the date and place of supply or first putting into service. - BS EN 12453:2017+A1:2021 Industrial, commercial and garage doors and gates. Safety in use of power operated doors. Requirements and test methods. - BS EN 12604 Industrial, commercial and garage doors and gates. Mechanical aspects. Requirements and test methods. - BS EN 13241 Industrial, commercial, garage doors and gates. Product standard, performance characteristics. - BS EN 12978, current edition: Industrial, commercial and garage doors and gates and pedestrian doorsets. Protective devices for power operated doors and gates. Requirements and test methods (for safety devices supplied as separate components). - DHF TS 013-1:2025 Code of practice for the safety of industrial doors, domestic garage doors, powered gates and traffic barriers. Part 1: On-site guide (supersedes the 2021 edition). - Workplace (Health, Safety and Welfare) Regulations 1992, where the barrier is in or serves a workplace. - BS 7671 Requirements for Electrical Installations (IET Wiring Regulations, 18th Edition, current amendment) and the Electricity at Work Regulations 1989. - Gate Safe guidance on the safe design, installation and maintenance of automated gates and barriers. - Manufacturer's installation and maintenance instructions. 1.5 Safety devices and force testing - Provide safety devices chosen from the risk assessment. As a minimum, consider: [photocells at height(s) and positions], [presence detection loops], [safety edge on arm], [arm lights], [warning light / beacon], [warning signs]. - Vehicle safety loop(s) or other presence detection to prevent the arm closing onto a vehicle: [required: number and position]. - Pedestrian route: the barrier must not be the means of pedestrian access. Provide [separate pedestrian route / guarding / signage] to discourage people walking through the barrier opening. - Where the closing arm can impact a person, measure forces at the test points set out in BS EN 12453 using a calibrated force testing instrument. Forces must be within the limits in BS EN 12453. Record results on the commissioning record. - Safety devices to be monitored (self-checked) where the risk assessment or BS EN 12453 requires it. - Fully automatic or remote operation, where the user cannot see the barrier, only where the risk assessment shows the level of protection is adequate for that mode. 1.6 Controls and integration - Control method(s): [access control reader / ANPR / intercom / push button / key switch / remote / timer / ticket system / other]. - Open command from: [list systems, e.g. Paxton Net2 access control: see clause 7; GSM intercom: see clause 8]. The named brand is for example only, as a preferred brand chosen from experience. - Free exit: [exit loop / exit reader / push button / none]. - Fire alarm interface: [arm to open / stay closed / none] on fire alarm signal, as agreed with the [fire strategy / client]. - Other interfaces: [car park management / CCTV / BMS / other]. - Control panel location: [integral / remote at location]. - All interfaces must be wired so that no external input can override or bypass the safety devices. 1.7 Electrical (BS 7671) - Power supply: [voltage] supply to [location], [by Contractor / by others], terminating in a local lockable isolator within [distance] of the equipment. - Protection: [RCD / RCBO type and rating], as required by BS 7671 and the manufacturer. - Earthing and bonding to BS 7671. - Cable routes and ducts: [by Contractor / by others], size [size] mm, with draw cords, from [location] to [location]. - Low-voltage and data cables to be in separate ducts from mains cables. - Provide an Electrical Installation Certificate (or Minor Electrical Installation Works Certificate where suitable) to BS 7671 for the power supply work done by the Contractor. 1.8 Groundworks and foundations: [included / by others] - Foundation: [size] to the manufacturer's details and [structural engineer's design, where required]. - Ducts, draw pits and loop slots: [included / by others]. - Surface reinstatement: [included / by others], to match [existing surface]. - Where by others: the Contractor must provide foundation and duct drawings to the groundworks contractor by [date / stage] and inspect the foundation before installation. 1.9 Finishes - Housing finish: [polyester powder coat / galvanised / stainless steel / manufacturer's standard], colour [RAL or BS colour]. - Arm: [colour], with [red and white reflective banding / other markings]. - Signage: [warning and instruction signs] to suit the risk assessment. 1.10 Testing and commissioning - Test and commission to the manufacturer's instructions, BS EN 12453 and DHF TS 013-1:2025. - Carry out and record: function tests of every control and interface; tests of every safety device; force tests where required; power-failure and manual-release tests; electrical tests to BS 7671. - Give the client [number] working days' notice of commissioning so they can attend. - Do not hand over until all tests are passed and recorded. 1.11 Documentation and handover Provide the handover pack described in clause 11, including the declaration of conformity, UKCA or CE marking evidence under the applicable regime, risk assessment, commissioning and force test records, and user and maintenance instructions in English. The installer acting as manufacturer must compile and retain the technical file for the enforcing authorities; it is not a client handover document. 1.12 Training Train [number] client nominees in safe daily use, manual release, what to do in a fault, and the owner's duties. Record attendance. 1.13 Warranty - Parts: [term] from the date of handover. - Labour: [term] from the date of handover. - Conditions: [e.g. warranty depends on planned maintenance being carried out by a competent person at the stated intervals; excludes vehicle impact, vandalism and misuse]. 1.14 Maintenance - Planned maintenance: [included for term / quoted separately], see clause 9. - Reactive maintenance: [included for term / quoted separately], see clause 10. 1.15 Product Product: use ending A or ending B below.
Product endings: named, or equivalent
Ending A (named product): Product: [manufacturer and model, e.g. Ditec model], as preferred by the client.
Ending B (or equivalent): Product: [manufacturer and model] or equivalent. Any equivalent must meet every requirement in this clause. Evidence of equivalence to be provided with the tender.